RAYTO CHEMRAY 240
HARGA: 135juta
Spect- Merk : RAYTO / CHEMRAY 240
- Buatan : China
Features :
- Automatic, Random Access
- Up to 240 test per hour
- Reagent pre-heating, liquid level detection
- Automatic 10 steps washimh system (optinal), Low carry-over
- Labor saving, simple programming and real walk-away operation
- 24 hours non-sto[ reagent cooling compartment
- Reagent open system, close system on request
- Micro-volume for sample and reagent
- User-friendly software based on Windows XP
Technical Spesification :
System Function
- Throughput : Up to 240 tests per hour
- Contents of the testing: Clinical chemistry, Immunoturbidimeteric
- Analytical modes: End-point, Two-point, Kinetic
- Progamming: Open system with user defined programs
- Automatic, Random Access
- STAT sample priority
Sample Tray
- Sample position: 40 positions in refrigerated for samples
- Samle volume: 3-45 uL, 0.5 uL adjustable
- Any position for standard and quality control setting
Reagent Tray
- Reagent positions : 40 position in refrigerated compartment
- Refrigerated temperature: 4-15 oC
- Reaction volume
R1: 180-450 uL, 1 uL adjustable
R2: 30-250 uL, 1 uL adjustable
Reaction Tray
- Reagent positions : 81 cuvettes, 9 cuvettes/strip
- Cuvette: optical length 5mm
- Reaction volume: 180-500 uL
- Reaction temperature: 37oC, Fluctuation ±0.1oC
- Independent mixing probe
- Cuvette washing (optional): Automatic 10 steps washing system
Probe
- Pre-heating for reagent
- Collision protection, Liquid level detection and Inventory checking
- Automatic inner and outer probe washing after every cycle, carry-over ,0.1%
Measuring and Optic System
- Lamp: Halogen lamp
- Absorbance range: 0-3.500Abs±1%
- Wavelengths: 8 wavelengths from 340-700nm including 340nm
405nm, 450nm, 510nm, 546nm, 578nm, 630nm, 670nm
- Resolution: 0.0001ABS
Working Condition
- Power supply: AC 100/240V50/60 Hz
- Temperature: 10-35oC
- Humidity: 35-80%
- Water consumption: Max 2.5 L/hour
- Dimensions: 800cm(L)*600cm(W)*650cm(H)
Gross weight : 80 KG